Building Diagnostic

Our staff in the Building Diagnostic Division are all experienced and competent in carrying out destructive and non-destructive investigation for different types of building structures which inter alia includes aging buildings, cantilevered canopies, fire damaged buildings and vehicular tunnels. In addition to those traditional tests, our Building Diagnostic Division possesses the latest testing equipment for carrying out Ultrasonic Pulse Velocity Test, R.C. Radar Test, Half-cell Potential Test, Resistivity Test, Carbonation Test and Chloride Diffusion Test on concrete structures. We also possess three sets of infrared thermo scanner to conduct Infrared Thermography Survey in detecting water leakage, debonding of wall tiles and delamination of concrete for buildings.

Pull-off Test of Tile

Rebound Hammer Test

At client's special request, we can conduct a complete survey to investigate the structural integrity of building and provide long-term monitoring services on the soundness of concrete structures.


Covermeter Test

Previous



29A,On Chuen Street, On Lok Tsuen, Fanling, N.T. Hong Kong
Techno Centre, 33 On Kui Street, On Lok Tsuen, Fanling, N.T. Hong Kong
28 On Kui Street, On Lok Tsuen, Fanling, N.T. Hong Kong
Tel : (852) 2677 2032, 2677 2138 Fax :(852) 2677 0351, 2677 4691 E-MAIL : castco@netvigator.com